VISOR
®
Communications manual
Auto shutter speed (BINARY)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Auto shutter speed (binary) request string to sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x06 Telegram length
5
Unsigned
Char
0x07 Auto shutter speed
6
Unsigned
Char
0xX1 Request version
Auto shutter speed (binary) response string from sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x0F Telegram length
5
Unsigned
Char
0x07 Auto shutter speed
6 - 7
Unsigned
Short
0xXX Error codes (Page 88)
8 - 11 Int 0xXX Auto shutter speed value
12 - 15 Int 0xXX Score
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during processing: Low
Supported interfaces:
Telegrams: Availability and supported interfaces
(Page 85)
06814859 - 1/24/2019-00 Page 202 EN