VISOR
®
Communications manual
Read sensor identity (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Read sensor identity (ASCII) request string to sensor
Byte no. Content Meaning
1 G
Read sensor identity2 S
3 I
4 1 Request version
Example: GSI1
Read sensor identity (ASCII) response string from sensor
Byte no. Content Meaning
1 G
Read sensor identity2 S
3 I
4
P
F
P Pass
F Fail
5 - 7 X Error codes (Page 88)
8 - 10 X Length of the following data
11 ... n X
Version of the firmware as well as information about the
hardware. Areas are clearly separated by a semicolon.
Example:
GSIP0000221.19.3.2; [[[Nicht definierte Variablevisor_object.PD V20-OB-A2-
W12]]]
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Page 165 EN 06814859 - 1/24/2019-00