VISOR
®
Communications manual
Set parameter (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Set parameter (ASCII) request string to sensor
Byte no. Content Meaning
1 S
Set Parameter
2 P
3
P
T
P Permanent
T Temporary
Permanent change affect all parameters, including those that
were previously only changed temporarily.
4 - 6 X Detector number
7 - 9 X Command: Reference string / set value *1) see below
10 - 14 X Length of reference string / value in Bytes (n)
15 ... n X Reference string / value
Example: SPP0010010044196
Set parameter (ASCII) response string from sensor
Byte no. Content Meaning
1 S
Set Parameter
2 P
3
P
T
P Permanent
T Temporary
Permanent change affect all parameters, including those that
were previously only changed temporarily.
4
P
F
P Pass
F Fail
06814859 - 1/24/2019-00 Page 116 EN