VISOR
®
Communications manual
sensor. The job will be run by job name. You can read the job names by using the "Read job
list" telegram, for example.
VISOR
®
Job settings
l Auto operating distance (ASCII / binary)
The "Auto operating distance" telegram can be used to have the operating distance for the
job be automatically determined.
l Set operating distance (ASCII / binary)
The "Set operating distance" telegram can be used to change the operating distance for
the job.
l Read operating distance (ASCII / binary)
The "Read operating distance" telegram can be used to read the current operating
distance for the job.
l Auto shutter speed (ASCII / binary)
The "Auto shutter speed" telegram can be used to have the shutter time for the job be
automatically determined.
l Set shutter speed (ASCII / Binary)
With the telegram "Set shutter speed", the shutter speed of the job can be changed. This
telegram can, for example, be used for brightness compensation.
l Read shutter speed (ASCII / Binary)
With the telegram "Read shutter speed", the set shutter speed of the job can be read.
l Set gain (ASCII / Binary)
With the telegram "Set gain", the gain of the job can be changed. This telegram can, for
example, be used for brightness compensation.
l Read gain (ASCII / Binary)
With the telegram "Read gain", the set gain of the job can be read.
l Set parameter (ASCII / Binary)
With the telegram "Set parameter", the detector parameters can be adjusted, e.g.
reference strings, detector thresholds.
l Read parameter (ASCII / Binary)
With the telegram "Read parameter", the set parameters of the detectors can be read.
l Set ROI (ASCII / Binary)
With the telegram "Set ROI", the position of the selected detector can be changed.
l Read ROI (ASCII / Binary)
With the telegram "Read ROI", the position of the selected detector can be read.
l Read job list (ASCII / Binary)
The "Read job list" telegram can be used to output a list of all available jobs on the VISOR
®
vision sensor.