VISOR
®
Communications manual
Calibration: Validate point list (BINARY)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Calibration: Validate point list (binary) request string to sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x05 Telegram length
5
Unsigned
Char
0x20 Calibration: Validate by Point List
Calibration: Validate point list (binary) response string from sensor
Byte no. Data type Content Meaning
1 - 4 Unsigned Int 0x19 Telegram length
5
Unsigned
Char
0x20 Calibration: Validate by Point List
6
Unsigned
Short
0xXX Error codes (Page 88)
8 - 9
Unsigned
Short
0xXX Current highest point pair index
10 - 13 Unsigned Int 0xXX
Deviation calibration, RMSE (root
mean square error)
14 - 17 Unsigned Int 0xXX Deviation calibration, mean
18 - 21 Unsigned Int 0xXX Deviation calibration, max.
22 - 25 Unsigned Int 0xXX Deviation calibration, min.
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during processing: No change
Supported interfaces:
Telegrams: Availability and
Page 231 EN 06814859 - 1/24/2019-00