VISOR
®
Communications manual
Set operating distance (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Set operating distance (ASCII) request string to sensor
Byte no. Content Meaning
1 S
operating distance2 F
3 C
4 1 Request version
5 X
0: Temporary
1: Permanent
6 X
Movement
0 - Absolute
1 - Relative
2 - Absolute with reinitialization
7 X
Unit
0 - 1/1000 millimeters
4 - steps
8 - 15 X Operating distance
Example: SFC111400000010
Set operating distance (ASCII) response string from sensor
Byte no. Content Meaning
1 S
operating distance2 F
3 C
4
P
F
P successful (Pass)
F Fail
5 - 7 X Error codes (Page 88)
Page 103 EN 06814859 - 1/24/2019-00