VISOR
®
Communications manual
Read job list (ASCII)
Telegrams: Availability and supported interfaces (Page 85)
Overview telegrams (Page 81)
Read job list (ASCII) request string to sensor
Byte no. Content Meaning
1 G
Get Job List2 J
3 L
Example: GJL
Read job list (ASCII) response string from sensor
Byte no. Content Meaning
1 G
Get Job List2 J
3 L
4
P
F
P successful (Pass)
F Fail
5 - 7 X Response version
8 - 10 X Number of jobs
11 - 13 X Active job number
NOTE:
The following byte sequence is repeated for each job from 1 to
"Number of jobs". The byte numbers shift accordingly.
14 - 16 X
Number of characters for the job name.
This can be used to specify a unique name
for job n.
17 ... n X
From this position, the name for job n
follows in the specified length.
n+1 ... n +
X
Number of subsequent bytes. A description
06814859 - 1/24/2019-00 Page 128 EN