VISOR
®
Communications manual
3 for job n can be specified.
n + 4 ... m X
From this position, the description for job n
follows in the specified length.
m + 1 ... m
+ 3
X
Number of subsequent bytes. This can be
used to specify a unique name for the
author of job n.
m + 4 ... k X
From this position, the name for the author
of job n follows in the specified length.
k + 1 ... k +
8
X Date of creation of job n.
k + 9 ... k +
16
X Date of last change of job n.
Example: GJLP001001001007testjob010DefaultJob004Test2014112720141128
Additional information:
Accepted in run mode: Yes
Accepted in config mode: No
Accepted when Ready is low: Yes
Status of Ready signal during processing: No change
Supported interfaces:
Telegrams: Availability and supported
interfaces (Page 85)
End of telegram: Max. 4 bytes (optional)
Page 129 EN 06814859 - 1/24/2019-00