VISOR
®
Communications manual
Position
Value Description
ASCII
length
[bytes]
Data
type
Available
for
Pos. X
X coordinate for the found position,
1/1000 [user unit]
1 ... 11
Signed
integer
Pos. Y
Y coordinate for the found position,
1/1000 [user unit]
1 ... 11
Signed
integer
Delta Pos.
X
X position delta between the taught object and
the found object,
1/1000 [user unit]
1 ... 11
Signed
integer
Delta Pos.
Y
Y position delta between the taught object and
the found object,
1/1000 [user unit]
1 ... 11
Signed
integer
Angle
Orientation of found object,
1/1000 [°]
1 ... 11
Signed
integer
Angle
(45)
Orientation of bounding box for found code [°], 1 ... 6
Signed
integer
06814859 - 1/24/2019-00 Page 178 EN