VISOR
®
Communications manual
+ 3 Char can be specified.
n + 4 ... m Char 0xXX
From this position, the description for Job 1 follows in
the specified length.
m + 1 ...
m+ 3
Unsigned
Char
0xXX
Number of subsequent bytes. This can be used to
specify a unique name for the author of job n.
m + 4 ... k Char 0xXX
From this position, the name for the author of job n
follows in the specified length.
k + 1 ... k
+ 8
Unsigned
Int
0xXX Date of creation of job n.
k + 9 ... k
+ 16
Unsigned
Int
0xXX Date of last change of job n.
Additional information:
Accepted in run
mode:
Yes
Accepted in config
mode:
No
Accepted when
Ready is low:
Yes
Status of Ready signal
during processing:
No change
Supported interfaces: Telegrams: Availability and supported interfaces (Page 85)
Page 219 EN 06814859 - 1/24/2019-00