Chapter 5 ā Operating the Library Monitoring Your Library
December 2019 User GuideāSpectra T200, T380, and T680 Libraries
161
The following table describes the severity ranking for messages.
Read the message(s), and follow any recommended steps.
Note: Some error messages are followed by a series of errors that
provide additional information. To understand the sequence of
events, scroll back to view the first error message that was
produced, then read the others for clarification.
If you need assistance, contact Spectra Logic Technical Support (see
Contacting Spectra Logic on page 7).
3. When you are finished reading the messages and complete the
appropriate actions, you can select and delete individual messages or
you can delete all of the messages.
Use Syslog
The BlueScale Syslog feature sends all system messages logged by the
library to a previously configured Syslog server. Syslog is a standard for
forwarding log messages over an Internet Protocol (IP) computer network.
It provides separation of the software that generates log messages from the
system that stores the messages.
Each system message the library sends to the Syslog server contains the
original system message posted by the library and the remedy information
associated with the system message.
Message Severity Description Response
Informational The library is working as intended. An
event occurred that generated
information about an operation or a
system component.
Example: The utility completed
successfully.
No action is required.
Warning The library is working as intended. An
event occurred that may require attention
to keep the library running at 100%.
Example: QuickScan did not complete,
but will retry.
If the event was unexpected,
determine the cause of the event
and take remedial steps.
Error The library operation is impaired and
requires user intervention.
Example: QuickScan did not complete, and
there is a tape stuck in a drive as a result.
Determine the cause of the error
and take remedial steps.
Fatal Error The library experienced an event that
prevents it from continuing operations.
Example: The robot is not responding.
Examine any additional
information in the message and
take the required remedial steps.