Appendix C — Specifications Library Specifications
December 2019 User GuideSpectra T200, T380, and T680 Libraries
535
Power Cord Specifications
The power cords included with the library are considered part of the
library and are not intended for use with any other equipment. See Supply-
End Connector Types on page 536 for the different types of cords available
from Spectra Logic.
Notes: Install the included cord locks to prevent the power cords
from being inadvertently disconnected from the AC input
connectors. If the male connector does not have a twist lock,
an additional grounding wire from the chassis to earth
ground is required. For instructions on installing cord locks
and the grounding wire, see Installing Cord Locks and
Chassis Grounding on page 461.
The supply-end connector is considered the disconnect for
the unit. Make sure that the socket-outlet for the AC
connections is in an accessible location near the library.
To use the library outside of North America, the power cord
must meet the specifications for that country, as described in
the following sections. If the male connector does not have a
twist lock, an additional grounding wire from the chassis to
earth ground is required.
North America 100 130 VAC Power Cord The criteria for a 100-volt to 130-
volt AC power cord in North America are as follows:
North America and Korea 200 240 VAC Power Cord The criteria for a
200-volt to 240-volt AC power cord in North America and Korea are as
follows:
WARNING
Risk of electrical shock. If you operate the library without locks on both ends of the
AC power cords, a permanent grounding wire must be installed between the power
supply bay and Earth ground.
Parameter Specification
Power cordage Three-conductor, 14 AWG
Power input connectors Male: NEMA 5-15P
Female: IEC 60320 C19
Parameter Specification
Power cordage SJT type, three-conductor, 14 AWG minimum
a
a. Power cord must comply with local electrical code.
Power input connectors Male: Connector must be of the proper type,
rating, and safety approval.
Female: IEC 60320 C13