097-55501-01 Revision M – January 2009 TimeHub 5500 Users Guide 153
Chapter 4 Testing and Configuring the TimeHub
Establishing a Connection to the TimeHub
Using TL1 Commands
Use the following procedure to configure the Ethernet parameters (IP Address,
Subnet Mask, and Gateway Address).
1. Establish a direct serial connection to the TimeHub as described in
Communicating by Serial Port, on page 149.
2. Use the Edit Equipment command to specify whether the automatic output
messages, and commands and responses will be carried separately on two
different ports or combined on one port.
ED-EQPT:::<ctag>:::AOMERGE=a;
where a = Y (combines automatic output messages, and commands and
responses on one port) or N (provides separate ports for automatic output
messages, and commands and responses
3. Issue the following command to copy the working memory to auxiliary memory.
CPY-MEM::NET:<ctag>::WKG,AUX;
4. Issue the following command to set the TimeHub 5500 IP address.
ED-EQPT:::<ctag>:::IPNEX=a.a.a.a;
where each a is an independent value between 0 and 255
To verify the parameter, issue the Retrieve Equipment command:
RTRV-EQPT:::<ctag>:::PARAMETER=IPNEX;
5. Issue the following command to set the subnetwork mask IP address.
ED-EQPT:::<ctag>:::IPSUBNETX=a.a.a.a;
where each a is an independent value between 0 and 255
Notes:
1. To verify the parameter, issue the Retrieve Equipment command:
RTRV-EQPT:::<ctag>:::PARAMETER=AOMERGE;
2. If the IP address of the manager matches ILPM1 or IPLM2, the
output will be merged, regardless of the AOMERGE value. In this
case, the local manager software is used, which does not support
having commands and events carried on separate ports. For
details on the ILPM1 and IPLM2 parameters, refer to the
TimeHub 5500 TL1 Reference Manual.

Table of Contents

Other manuals for Symmetricom TimeHub 5500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeHub 5500 and is the answer not in the manual?

Symmetricom TimeHub 5500 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeHub 5500
CategoryData Loggers
LanguageEnglish

Related product manuals