1.2.5.1 Safety specifications
1.2.5.1.1 System requirements
Required Firmware
v4.2.0 or higher
Supported Hardware
SOMANET Circulo 7
SOMANET Circulo 9
1.2.5.1.2 Technical specifications
Safety parameters
Safety Integration level (SIL) according to IEC
61508:2010
SIL 3
Performance Level (PL) according to ISO 13849-
1:2015
PL e
Reaction time 10 ms
Safety parameters IEC 61508:2010
Probability of dangerous failure per hour (PFH ) 1.59∙10 /hour
Probability of dangerous failure on demand (PFD
)
1.39∙10
Safe Failure Fraction (SFF) 99.95%
Hardware Fault Tolerance (HFT) 1
HW-type Type A
Mission time T 20 a
Supported safety modes High, Low
Safety parameters ISO 13849-1:2015
Category Cat. 3
Mean Time to dangerous Failure (MTTF ) 3319 years (capped to 100 years)
Diagnostic coverage (DC ) 99%
d
-10
avg
-5
M
d
avg
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 112/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node Series and is the answer not in the manual?

SYNAPTICON SOMANET Node Series Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node Series
CategoryServo Drives
LanguageEnglish

Related product manuals