3.1.9.1.70 0x21FF Singleturn offset
undefined
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Sensor 1 0x21FF:1 UDINT 32 0 Inc readwrite
Value to substract from the singleturn value received from Sensor 1. Only applicable to absolute encoders.
This parameter has to be lower than the resolution of the encoder.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Sensor 2 0x21FF:2 UDINT 32 0 Inc readwrite
Value to substract from the singleturn value received from Sensor 2. Only applicable to absolute encoders.
This parameter has to be lower than the resolution of the encoder.