3.1.9.1.128 0x6073 Max current
Indicates the configured maximum permissible torque-creating current in the motor. The units are per
thousand of rated current.
For example, if the 0x6075 Motor rated current is 2 Amps, setting the Max current to 3000 would imply
the motor can survive 6 Amps of current for short periods.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Max current 0x6073:0 UINT 16 0 50000 3000 readwrite Receive
PDO
(Outputs)