3.1.9.1.154 0x60E3 Supported homing methods
List of the homing methods supported by the drive.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Method 01 0x60E3:1 SINT 8 37 readonly
(default)
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Method 02 0x60E3:2 SINT 8 35 readonly
(default)
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Method 03 0x60E3:3 SINT 8 34 readonly
(default)
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Method 04 0x60E3:4 SINT 8 33 readonly
(default)