3.1.9.1.139 0x6080 Max motor speed
Sets the max allowed speed for the motor in either direction. It is used to protect the motor and is taken from
the motor data sheet. The value shall be given in user-defined units (RPM by default; see 0x60a9 SI unit
velocity to change it).
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Max motor
speed
0x6080:0 UDINT 32 0 1000 rpm readwrite Receive
PDO
(Outputs)
Synapticon Documentation