3.1.9.1.124 0x606F Velocity threshold
Configures the velocity that is considered zero velocity. The units are user-defined (RPM by default; see
0x60a9 SI unit velocity to change it).
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Velocity
threshold
0x606F:0 UINT 16 0 rpm readwrite Receive
PDO
(Outputs)
Synapticon Documentation