EasyManuals Logo
Home>SYNAPTICON>Servo Drives>SOMANET Node Series

SYNAPTICON SOMANET Node Series User Manual

Default Icon
887 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #125 background imageLoading...
Page #125 background image
1.2.5.5.1 Emergency stop
The STO and SBC functions can be used for implementing the category 0 emergency stop function according
to IEC 60204-1:2016.
The Emergency stop function can be realized
With an emergency stop switch connected directly to control the STO-SBC input signals
With an emergency stop relay + emergency stop switch.
With safety PLC + emergency stop switch.
Please read the section about the working principle of the Safety circuit.
All cases above requires correct behaviour from the controlling PLC. After releasing the emergency stop
device, a separate and deliberate action must be used to restart the system (restarting can be done with a non-
safety PLC).
Attention
IEC 60204-1:2016 requires “reset shall not initiate a restart” regarding emergency stop.
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 125/887