3.1.9.1.53 0x2013 Gain scheduling
Name Index:Sub Type Bit
Size
Options Unit Access PDO
Mapping
Enabled 0x2013:1 BOOL 1
Disabled 0
Enabled 1
readwrite
Enables or disables the gain scheduling feature.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Threshold
velocity 0
0x2013:2 UDINT 32 0 0 rpm readwrite
Velocity that determines the lower threshold. Underneath this value, controller gains set 0 is used. Beyond
it, linear interpolation begins.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position loop Kp
0
0x2013:3 REAL 32 0 65535 0 readwrite
The P-gain of the Position Control Loop of area 0 (low velocity, below threshold velocity 0) [rpm/inc]
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position loop Ki
0
0x2013:4 REAL 32 0 65535 0 readwrite
The I-gain of the Position Control Loop of area 0 (low velocity, below threshold velocity 0) [rpm/(inc*s)]
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position loop Kd
0
0x2013:5 REAL 32 0 65535 0 readwrite
The D-gain of the Position Control Loop of area 0 (low velocity, below threshold velocity 0) [rpm*s/inc]
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Position loop
integral limit 0
0x2013:6 UDINT 32 0 0 rpm readwrite
The integrator limit of the Position Control Loop of area 0 (low velocity, below threshold velocity 0).
Technique used for preventing the windup is clamping and it prevents the integral term from accumulating
above or below pre-determined bounds. Limit should always be set in the driving shaft units, especially
important, when the gear box is used in the setup.
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Velocity loop Kp
0
0x2013:7 REAL 32 0 65535 0 readwrite
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 639/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node Series and is the answer not in the manual?

SYNAPTICON SOMANET Node Series Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node Series
CategoryServo Drives
LanguageEnglish

Related product manuals