Pin # Signal Function Object Mapping
1 +5 V * Supply for external use 100 mA max
2 Analog In 2 - Differential - ** Analog input 2 (0x2402)
3 Analog In 2 + Differential + ** Analog input 2 (0x2402)
4 GND Ground
5 Analog In 1 Single-ended 0-5 V Analog input 1 (0x2401)
6 +10 V*** Supply for external use 25 mA max
* The supply is protected against short to ground and keeps the current below 400mA in a continuous short.
** V = 5 V; Common mode voltage V = -1…5V.
*** The supply is protected against short to ground and keeps the current below 100mA in a continuous
short.
The Analog Inputs have a 12 bit resolution
diff,max cm
1.2.6.2.1.2.2.1 Analog input resistance
1.2.6.2.1.2.2.1.1 Differential
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 153/887