EasyManuals Logo

SYNAPTICON SOMANET Node Series User Manual

Default Icon
887 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #348 background imageLoading...
Page #348 background image
P-PI configuration focuses on soft damped step response. It has a slower response and less precise
tracking, however it is usually possible to fully avoid overshoot. Additionally, it is more sensitive to
noise in the velocity signal:
2. The controller gains are updated automatically every time the sliders are dragged and released. The gains
calculation has an optimization loop inside and may take a few seconds.
3. After the initial tuning is done, it is possible to tune the control loop more precisely by changing the gains
while executing a test signal. There are currently 4 repeatable test signals: square wave, ramp, bidirectional
ramp and sine. It is possible to drag sliders and manually change gains during the reference signal
following:
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 348/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node Series and is the answer not in the manual?

SYNAPTICON SOMANET Node Series Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node Series
CategoryServo Drives
LanguageEnglish

Related product manuals