Integral constant Ki in PID phasing controller. This controller is used to hold the position during offset
detection procedure.
WARNING: If not tuned, the default values of "phasing controller" do not guarantee a stable situation. Before
using "offset detection method 1" tune its "phasing controller" for your mechanical load. If you want to tune
"phasing controller" of "offset detection method 1" make sure that your motor can freely rotate at high
speeds (recommendation: start tuning by setting kp = 1, ki = 1, and kd = 0).
Name Index:Sub Type Bit
Size
Min
Data
Max
Data
Default
Data
Unit Access PDO
Mapping
Phasing
controller Kd
0x2009:6 REAL 32 0 0 readwrite
Derivative constant Kd in PID phasing controller. This controller is used to hold the position during offset
detection procedure.
WARNING: If not tuned, the default values of "phasing controller" do not guarantee a stable situation. Before
using "offset detection method 1" tune its "phasing controller" for your mechanical load. If you want to tune
"phasing controller" of "offset detection method 1" make sure that your motor can freely rotate at high
speeds (recommendation: start tuning by setting kp = 1, ki = 1, and kd = 0).
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 623/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node Series and is the answer not in the manual?

SYNAPTICON SOMANET Node Series Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node Series
CategoryServo Drives
LanguageEnglish

Related product manuals