Select desired number of pulses in one sinewave.
This value is going to be used to calculate the singleturn resolution (Resolution).
Name Index:Sub Type Bit
Size
Options Unit Access PDO
Mapping
Sinusoidal
output
voltage
0x220E:8 USINT 8
up to 50 mVpp 15
up to 60 mVpp 14
up to 75 mVpp 13
up to 0.1 Vpp 12
up to 0.12 Vpp 11
up to 0.14 Vpp 10
up to 0.15 Vpp 9
up to 0.2 Vpp 8
up to 0.28 Vpp 7
up to 0.4 Vpp 6
up to 0.5 Vpp 5
up to 0.6 Vpp 4
up to 0.75 Vpp 3
up to 1 Vpp 2
up to 1.2 Vpp 1
up to 1.5 Vpp 0
readwrite
Differential voltage in the Sin/Cos outputs peak to peak.
It is often abreviated as Vpp.
Name Index:Sub Type Bit
Size
Options Unit Access PDO
Mapping
Index
availability
0x220E:9 BOOL 1
Encoder without
index
0
Encoder with index 1
readwrite
Define if the connected encoder has an index or not.
The index is often called "reference".
Synapticon Documentation
© 2021 Synapticon GmbH | Daimlerstraße 26 | D-71101 Schönaich Documentation v 4.11.0 | Built 2021-07-23 714/887

Table of Contents

Other manuals for SYNAPTICON SOMANET Node Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SYNAPTICON SOMANET Node Series and is the answer not in the manual?

SYNAPTICON SOMANET Node Series Specifications

General IconGeneral
BrandSYNAPTICON
ModelSOMANET Node Series
CategoryServo Drives
LanguageEnglish

Related product manuals