WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0 34 2018-02-16
PRELIMINAR
Y
Response
Table 35, page 34, describes the responses and remarks for Read File command.
Synchronous Response
Table 36, page 34, describes the synchronous responses and remarks for Read File
command.
Table 34 Read File Parameters
Parameters Mandatory/Optional Value Description
File
Descriptor
Mandatory
Value range:
0X0-0XFFFFFFFF
Format: Hexa
Default value:
N/A
It specifies the value returned while
opening a file.
Offset Mandatory
Value range:
0-1024
Format: Integer
Default value:
N/A
It specifies offset from the starting of the
file.
Length Mandatory
Value range:
0-1024
Format: Integer
Default value:
N/A
It specifies the number of bytes to read
Table 35 Read File Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.
Table 36 Read File Synchronous Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.