WE866E4-P AT Commands Reference Guide
80572ST10887A Rev. 0.0 53 2018-02-16
PRELIMINAR
Y
Response
Table 85, page 53, describes the responses and remarks for AP Configuration command.
Synchronous Response
Table 86, page 53, describes the synchronous responses and remarks for AP Configuration
command.
Hidden SSIDMandatory
Value range: 0,1
Format: Integer
Default value: 0
It specifies the hidden SSID created for a
Network, where:
0- disables the hidden SSID and
1-enables the hidden SSID
Beacon
Interval
Mandatory
Value range:
100-1000
Format: Integer
Default value: 100
Unit: TUs
It specifies the interval between the beacon
frames coming from access point.
It is measured in TUs (Time Units) where,
One TU is 1024 microseconds.
DTIM
Period
Mandatory
Value range:
1-255
Format: Integer
Default value: 3
Unit: seconds
DTIM (Delivery Traffic Indication Map)
depends on the Beacon Interval.
It specifies that when DTIM enabled
beacon frame arrives, station wakes up
with a default period value 3. So for every
three beacons, connected sleeping stations
wakes up and receive the beacon frames.
Table 84 AP Configuration Parameters
Parameters Mandatory/Optional Value Description
Table 85 AP Configuration Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.
Table 86 AP Configuration Synchronous Response
Responses Remarks
OK Success.
ERROR If parameter is not valid.