INPUT/OUTPUT(continued)
Iftheproperinputsandqualiersexist,thefollowingoutputsshouldoccur
(Figure169):
•Thestartrelayshouldbeenergized,thestartermotorshouldengageandthe
electricfuelpumpshouldbeenergized(STARTON)and(OKRUNON).
AirFilter
g288333
Figure170
Theairlterdiagnosticscreenidentiesthestateoftheengineairlterservice
indicator(Figure170).
•Duringnormaloperatingconditions(AIRFILTEROFF)shoulddisplay.
•Iftheengineairlterbecomesdirtyorblocked,ahighvacuumcondition
occursand(AIRFILTERON)shoulddisplay.
FAULTVIEWER
1
2
3
4
5
6
90 726.7 24 27
5 708.5 5.4 4
92 517.1 517.0 3
91 517.1 517.0 4
12 516.9 472.7 2
97 516.9 516.9 1
g288334
Figure171
1.Button14.Button4
2.Button25.Button5
3.Button3
6.Machinefaults
MachinefaultsaregeneratedbytheToroElectronicControllers(TEC)toidentify
anelectricalsystemmalfunction(fault)thatoccursduringmachineoperation.
Whenamachinefaultoccurs,anaudiblealarmwillsoundandtheInfoCenter
willdisplayinformationaboutthefault.Machinefaultscanbeviewedviathe
ElectricalSystem:InfoCenterDisplay
Page6–34
Groundsmaster
®
5900&5910