1. IDLE
0X00 ENG HRS − 100 VOLTAGE LOW
SPN − 3251 FMI − 4
OCC CNT − 1
1
2
3
4
5
6
g287510
Figure12
1.Button14.Button4
2.Button25.Button5
3.Button3
6.Enginefaultdescription
3.ThefaultdescriptionwillbedisplayedontheInfo-Center(Figure12).Press
button3tosilencetheaudiblealarm.Pressbuttons1and2toscrollthrough
thelistofactiveenginefaults.
4.IfaSTOPfaultisdisplayedontheInfoCenter,theoperatorshouldcease
operationofthemachineandtheengineasquicklyandassafelyaspossible
toreducedamagetotheengine.
5.IfaCHECKENGINEfaultisdisplayedontheInfo-Center,theoperator
shouldtakethemachineforserviceassoonaspossible.
6.Returntothepreviousscreenbypressingbutton5.
AniconwillappearintheupperleftcorneroftheOperator’sInformation
screenaslongasanenginefaultisactive(Figure11).Inordertoclearthe
displayedfault,theengineproblemhastoberesolved.SeetheYanmarEngine
TroubleshootingandYanmarServiceManualforadditionalinformation.
Note:EnginefaultsthatarenolongeractivearestoredintheYanmarEngine
ElectronicControlunit(ECU)andcanonlybeviewedbyusingtheYanmar
SMARTASSIST−Directdiagnosticsoftware.
Troubleshooting:Page3–28
Groundsmaster
®
5900&5910
16227SLRevB