EasyManua.ls Logo

TR-Electronic MP Series - Page 165

TR-Electronic MP Series
252 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Printed in the Federal Republic of Germany TR-Electronic GmbH 2008, All Rights Reserved
06/06/2019 TR - EMO - BA - DGB - 0019 - 08 Page 165 of 252
encoTRive response if carried out successfully:
Byte
Value
Meaning
0
Request Reference
1
0x01
Parameter read successfully
2
0x00
Axis
3
0x01
1 Parameter
4
0x41
Format: Byte
5
0x2E
Number of values: 46
6
0x40
Identifier: 0x4006: Array from UNSIGNED16
7
0x06
8
0x00
Number of array elements: 6
9
0x06
10
0x3F
Normalization factor: Floating-point number 1.0
11
0x80
12
0x00
13
0x00
14
0x00
Attribute: 0x0000
15
0x00
16
0x00
reserved
17
0x00
18
0x00
19
0x00
20
0x50
‚P’
Name: “PZD Setpt.conf.”
21
0x5A
‚Z’
22
0x44
‚D’
23
0x20
‚ ‚
24
0x73
‚S’
25
0x65
‚e’
26
0x74
‚t’
27
0x70
‚p’
28
0x74
‚t’
29
0x2E
‚.’
30
0x63
‚c’
31
0x6F
‚o’
32
0x6E
‚n’
33
0x66
‚f’
34
0x2E
‚.’
35
0x00
36
0x00
Lower limit value: 0x00000000
37
0x00
38
0x00
39
0x00
40
0x00
Upper limit value: 0x0000FFFF
(65535)
41
0x00
42
0xFF
43
0xFF
44
0x00
Reserved / ID extension / PZD Ref. / PZD
normalization
45
0x00
46
0x00
47
0x00
48
0x00
49
0x00
50
0x00
51
0x00

Table of Contents