July, 2007
4-39
WorkCentre 5020
REP 6.1.1
Repairs and Adjustments
Initial Issue
REP 6.1.1 Exit Transport
Parts List on PL 6.1
Removal
WARNING
To avoid personal injury or electrical shock, ensure that the machine is completely off
before disassembling or adjusting. Turn OFF the power and unplug the machine.
WARNING
The Fuser and Exit Transport are hot. Do not work on them until they are cool enough.
1. Open the Left Side Cover.
2. Remove the Rear Cover (REP 9.2.1).
3. Disconnect the connector (Figure 1).
1 Disconnect P/J 505.
2 Remove the wire harness from the hook.
3 Remove the wire harness from the guides (2).
4 Release the wire harness from the clamps (2).
Figure 1