July, 2007
2-22
WorkCentre 5020
Initial Issue
Status Indicator RAPS
N9-0
Error Name
Controller Logic fail
Explanation
A software defect that cannot be ignored is found in the Controller software.
Check Items
Turn the power OFF then ON.
O -
CH3.2
Figure 2
N9-1
Error Name
IOT Communication Error
Explanation
The AIOC PWB has detected a Type-Di communication error.
Check Items
Turn the power OFF then ON.
O -
CH3.2
Figure 2
U0-1
Error Name
Main Motor stop error
Explanation
The motor runs for over 120 seconds without any paper being fed.
O U0-1
CH4.1
Figure 1
U1-1
Error Name
Main Motor rotation error
Explanation
500ms after the IOT has started, the Main Motor Lock signal is "Low."
O U1-1
CH4.1
Figure 1
U2-1
Error Name
Carriage Module Fail
Explanation
An abnormality was detected in the Carriage Module.
O U2-1
CH6.2
Figure 2
U3-5
Error Name
Laser Power or ROS Motor Fail
Explanation
• The ROS Motor is unable to rotate.
• Or, the laser output is not normal.
O U3-5
CH6.3
Figure 3
U4-1
Error Name
Fuser On Time Fail
Explanation
• The lamp did not turn OFF within the specified time after turning ON.
• Or, Warm Up was not completed within the specified time after power ON.
O U4-1
CH10.1
Figure 1
U4-2
Error Name
Over Heat Temp Fail
Explanation
A temperature above 250°C is continuously detected for 480ms.
O U4-2
CH10.1
Figure 1
U4-3
Error Name
FS1 thermistor defect
Explanation
FS1 cannot be monitored any more.
O U4-3
CH10.1
Figure 1
Error
Code Error Name/Explanation/I/O Diagnostic Codes/Check Items
Record in
Error Log RAP BSD