February, 2008
6-17
WorkCentre 5225, 5230
IOT NVM List
General Procedures
Launch Version
751-034 TRAY1 for Heavyweight3 Paper - LEAD REGI
ADJUSTMENT
33 0~66 0.363mm Image input is delayed when Set Value is increased.
751-035 TRAY2-4, HCF for Heavyweight3 Paper - LEAD
REGI ADJUSTMENT
33 0~66 0.363mm Image input is delayed when Set Value is increased.
751-036 MPT for Heavyweight3 Paper - LEAD REGI
ADJUSTMENT
33 0~66 0.363mm Image input is delayed when Set Value is increased.
751-037 DUP ALL SIZE for Heavyweight3 Paper - LEAD
REGI ADJUSTMENT
33 0~66 0.363mm Image input is delayed when Set Value is increased.
751-560 Component Control Independent Output Selection 0 0~1 1 0: Simultaneous Output (Independent Output disabled) 1: Independent Output
751-849 Drum Cycle Count, 1st and 2nd digits 0 0~99 1
Used only in mode for countries where wireless transmission is inhibited.
751-849 Drum Cycle Count, 3rd and 4th digits 0 0~99 1
751-849 Drum Cycle Count, 5th and 6th digits 0 0~99 1
751-881 BCR Iac Control Threshold Value of the Number of
Drum Cycles
1 0~40 10 kHz Valid when BCR Iac control change is On (the value is 1).
751-882 BCR Iac Output SC UNDER
(Temperature is less than 11deg.C. The number of
drum cycles is less than the threshold value.)
100 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (100): 1.6 mA
751-883 BCR Iac Output SC OVER
(Temperature is less than 11deg.C. The number of
drum cycles is more than or equal to the threshold
value.)
67 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (67): 1.55 mA
751-884 BCR Iac Output C UNDER
(Temperature is from 11deg.C to less than 20deg.C.
The number of drum cycles is less than the thresh
-
old value.)
50 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (50): 1.45 mA
751-885 BCR Iac Output C OVER
(Temperature is from 11deg.C to less than 20deg.C.
The number of drum cycles is more than or equal to
the threshold value.)
50 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (17): 1.35 mA
751-886 BCR Iac Output B UNDER
(Temperature is from 20deg.C to less than 28deg.C.
The number of drum cycles is less than the thresh
-
old value.)
33 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (33): 1.40 mA
751-887 BCR Iac Output B OVER
(Temperature is from 20deg.C to less than 28deg.C.
The number of drum cycles is more than or equal to
the threshold value.)
33 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (0): 1.3 mA
751-888 BCR Iac Output A UNDER
(Temperature is 28deg.C or more. The number of
drum cycles is less than the threshold value.)
33 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (0): 1.3 mA
751-889 BCR Iac Output A OVER
(Temperature is 28deg.C or more. The number of
drum cycles is more than or equal to the threshold
value.)
33 0~100 1% Valid when BCR Iac control change is On (the value is 1). Min (0): 1.30 mA, Max (100):
1.6 mA, init (0): 1.3 mA
Table 11 XERO
Chain-