16.2 List of Parameters
16.2.2 List of Parameters
16-24
PnB05
2
/PGMRES; /JOGP
0000h to
0003h
0000h All
After
restart
Setup
page
6-5
PnB06
2
/SEL0; /JOGN
0000h to
0003h
0000h All
After
restart
Setup
page
6-6
PnB07
2
/SEL1; /JOG0
0000h to
0003h
0000h All
After
restart
Setup
page
6-6
PnB08
2
/SEL2; /JOG1
0000h to
0003h
0000h All
After
restart
Setup
page
6-6
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
0000h
When /MODE signal is ON (closed) (mode 0): Resets and cancels program table opera-
tion by switching the /PGMRES signal from OFF (open) to ON (closed).
When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the forward
direction while the /JOGP signal is ON (closed).
0001h
When /MODE signal is ON (closed) (mode 0): Resets and cancels program table opera-
tion by switching the /PGMRES signal from ON (closed) to OFF (open).
When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the forward
direction while the /JOGP signal is OFF (open).
0002h,
0003h
When /MODE signal is ON (closed) (mode 0): Program table operation is not reset.
When /MODE signal is OFF (open) (mode 1): Does not execute JOG operation.
0000h
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is active when ON
(closed).
When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the reverse
direction while the /JOGN signal is ON (closed).
0001h
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is active when OFF
(open).
When /MODE signal is OFF (open) (mode 1): Executes JOG operation in the reverse
direction while the /JOGN signal is OFF (open).
0002h
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always active.
When /MODE signal is OFF (open) (mode 1): Does not execute JOG operation.
0003h
When /MODE signal is ON (closed) (mode 0): The /SEL0 signal is always inactive.
When /MODE signal is OFF (open) (mode 1): Does not execute JOG operation.
0000h
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is active when ON
(closed).
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is active when ON
(closed).
0001h
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is active when OFF
(open).
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is active when OFF (open).
0002h
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always active.
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always active.
0003h
When /MODE signal is ON (closed) (mode 0): The /SEL1 signal is always inactive.
When /MODE signal is OFF (open) (mode 1): The /JOG0 signal is always inactive.
0000h
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is active when ON
(closed).
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is active when ON
(closed).
0001h
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is active when OFF
(open).
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is active when OFF (open).
0002h
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always active.
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always active.
0003h
When /MODE signal is ON (closed) (mode 0): The /SEL2 signal is always inactive.
When /MODE signal is OFF (open) (mode 1): The /JOG1 signal is always inactive.