5
Outline of Motion Control Systems
5.2.4
Motion Programs and MSEE and S Registers
5-14
( 2 ) Motion Program Control Signals (DAxxxxx+1)
Program control signals (e.g., program operation start requests and program stop requests) need to be
entered to execute the motion program called from DWG.H using the MSEE command. The second
word of the MSEE work registers (DAxxxxx+1) is the motion program control signal.
The following types of signals for controlling motion programs are available.
These signals can perform run, stop, hold, and other controls for motion programs by entering from
the ladder program to the work register specified by the MSEE command +1.
Use signals conforming to the above signal types when writing ladder programs.

Motion programs are executed if the program operation start request signal is ON when the power
is turned ON (e.g., when a start request signal is left in M register).
â– 
Timing Chart for Motion Program Control Signals
The following figure shows an example of a timing chart for motion program control signals.
Bit No. Signal Name Signal Type
0 Program operation start request Differential or NO contact input
1 Program pause request NO contact
2 Program stop request NO contact
3 Program single block mode selection NO contact
4 Program single block start request Differential or NO contact input
5 Alarm reset request NO contact
6 Program continuous operation start request Differential or NO contact input
8 Skip 1 information NO contact
9 Skip 2 information NO contact
D System work number setting
NO contact
OFF: The system will use the automatically obtained system work
number. The system work number may be different each time.
ON: The work with the set system work number will be used.
E Interpolation override setting
NO contact
OFF: Interpolation override 100% fixed
ON: Conforms to set interpolation override
Control signal: Operation start request
Status: Operating
Distribution
One scan
Program Operation Start Request
Control signal: Operation start request
Status: Operating
Distribution
Control signal: Pause request
Status: Paused
Pause Request

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA JEPMC-MP2300-Y Series and is the answer not in the manual?

YASKAWA JEPMC-MP2300-Y Series Specifications

General IconGeneral
BrandYASKAWA
ModelJEPMC-MP2300-Y Series
CategoryController
LanguageEnglish

Related product manuals