Page #540 background imageLoading...
Page #540 background image
11
Precautions for Using the MP2300
11.3.2
Precautions When Saving SERVOPACK Parameters
11-16
( 7 ) Saving Data to Flash Memory
The data flow for SERVOPACK parameters is as follows when saving the parameters to flash
memory on the MPE720:
• The MP2300 writes the parameters data (Input Data) held in SDRAM to flash memory.

Save to flash memory also after having changed set data of SERVOPACK parameter.
11.3.2 Precautions When Saving SERVOPACK Parameters
Before executing saving operation in the SERVOPACK Tab Page in any cases including the SERVO-
PACK replacement, always select Edit - Copy Current Value to copy the values in Current Value to
Input Data.
MECHATROLINK
RAM
EEP
-ROM
SRAM
SDRAM
Input
Data
MPE720 ã§”onlineã§•
HDD in personal computer
Display
Current
Value
Input
Data
Flash
Memory
System
Software
Control
Software
Servo Parameters
(All Axes)
Parameters
SERVOPACK SERVOPACK
Send Send
MP2300