2.1
Model System Startup Procedure
2-31
5.
Select File (F) - Save (S) to save the SERVOPACK settings for axis 1 to the MP2300.
6.
Refer to steps 2 to 5 to write and save the SERVOPACK current position for axis 2 as
settings data, using the same procedure as for axis 1.
7.
Select File - Exit to exit the setting and saving process in the Engineering Manger
Window.
( 6 ) Saving to Flash Memory
Save sample programs that have been transferred individually to the MP2300 to the MP2300 flash
memory using the procedure below.
1.
Right-click the Controller Folder in which the sample programs have been saved and
select Transfer - Other - Save to Flash from the pop-up menu that is displayed.
The Save Flash Memory Content Window will appear.