show fiber-ports optical-transceiver 111
Example
The following example displays the optical transceiver diagnostics results.
Console#
show fiber-ports optical-transceiver 21
Curre
nt
Output
Port Temp Volta
ge
Power Power Input LOS
---- ---- -----
--
-----
--
-----
-
----- ---
21 OK OK OK OK OK No
Temp – Internally measured transceiver temperature.
Voltage - Internally measured supply voltage.
Current – Measured TX bias current.
Output Power – Measured TX output power in milliWatts.
Input Power – Measured RX received power in milliWatts.
LOS – Loss of signal
N/A - Not Available, N/S - Not Supported, W - Warning, E - Error