User's Manual 964 Document #: LTRT-10466
Mediant 500L MSBR
Parameter Description
200 OK immediately upon receipt of the BYE to disconnect
from the IP phone. The call is disconnected from the Tel
side only when the call duration is greater than or equal to
the minimum call duration.
Notes:
This parameter is applicable to IP-to-Tel and Tel-to-IP
calls.
This parameter is applicable only to ISDN and CAS
protocols.
Web/EMS: Disconnect on Dial Tone
CLI: disc-on-dial-tone
[DisconnectOnDialTone]
Determines whether the device disconnects a call when a
dial tone is detected from the PBX.
[0] Disable = (Default) Call is not released.
[1] Enable = Call is released if a dial tone is detected on
the device's FXO port.
Notes:
This parameter is applicable only to FXO interfaces.
This option is in addition to the mechanism that
disconnects a call when either busy or reorder tones are
detected.
Web: Send Digit Pattern on Connect
EMS: Connect Code
CLI: digit-pttrn-on-conn
[TelConnectCode]
Defines a digit pattern to send to the Tel side after a SIP
200 OK is received from the IP side. The digit pattern is a
user-defined DTMF sequence that is used to indicate an
answer signal (e.g., for billing).
The valid range is 1 to 8 characters.
Note: This parameter is applicable only to FXO/CAS.
Web: Disconnect on Broken Connection
EMS: Disconnect Calls on Broken
Connection
CLI: disc-broken-conn
[DisconnectOnBrokenConnection]
Global parameter that enables the device to release calls if
RTP packets are not received within a user-
defined timeout
(configured by the BrokenConnectionEventTimeout
parameter). You can also configure this functionality per
specific calls, using IP Profiles
(IpProfile_DisconnectOnBrokenConnection). For a detailed
description of this parameter and for configuring this
functionality in the IP Profile table, see ''Configuring IP
Profiles'' on page
332.
Note: If this functionality is configured for a specific IP
Profile, the settings of this global parameter is ignored for
calls associated with the IP Profile.
Web: Broken Connection Timeout
EMS: Broken Connection Event
Timeout
CLI: broken-connection-event-timeout
[BrokenConnectionEventTimeout]
Defines the time period (in 100-msec units) after which a
call is disconnected if an RTP packet is not received.
The valid range is from 3 (i.e., 300 msec) to an unlimited
value (e.g., 20 hours). The default is 100 (i.e., 10000 msec
or 10 seconds).
Notes:
This parameter is applicable only if the parameter
DisconnectOnBrokenConnection is set to 1.
Currently, this feature functions only if Silence
Suppression is disabled.