User's Manual 67. Configuration Parameters Reference
Version 6.8 965 Mediant 500L MSBR
Parameter Description
Web: Disconnect Call on Silence
Detection
EMS: Disconnect On Detection Of
Silence
CLI: disc-on-silence-det
[EnableSilenceDisconnect]
Determines whether calls are disconnected after detection
of silence.
[1] Yes = The device disconnects calls in which silence
occurs (in both call directions) for more than a user-
defined time.
[0] No = (Default) Call is not disconnected when silence
is detected.
The silence duration can be configured by the
FarEndDisconnectSilencePeriod parameter (default 120).
Note: To activate this feature, set the parameters
EnableSilenceCompression and
FarEndDisconnectSilenceMethod to 1.
Web: Silence Detection Period [sec]
EMS: Silence Detection Time Out
[FarEndDisconnectSilencePeriod]
Defines the duration of the silence period (in seconds) after
which the call is disconnected.
The range is 10 to 28,800 (i.e., 8 hours). The default is 120
seconds.
Note: For this parameter to take effect, a device reset is
required.
Web: Silence Detection Method
[FarEndDisconnectSilenceMethod]
Determines the silence detection method.
[0] None = Silence detection option is disabled.
[1] Packets Count = According to packet count.
Note: For this parameter to take effect, a device reset is
required.
[FarEndDisconnectSilenceThreshold]
Defines the threshold of the packet count (in percentages)
below which is considered silence by the device.
The valid range is 1 to 100%. The default is 8%.
Notes:
This parameter is applicable only if silence is detected
according to packet count
(FarEndDisconnectSilenceMethod is set to 1).
For this parameter to take effect, a device reset is
required.
[BrokenConnectionDuringSilence]
Enables the generation of the BrokenConnection event
during a silence period if the channel’s NoOp feature is
enabled (using the parameter NoOpEnable) and if the
channel stops receiving NoOp RTP packets.
[0] Disable (default)
[1]
Enable
Web: Trunk Alarm Call Disconnect
Timeout
CLI: trk-alrm-call-disc-to
[TrunkAlarmCallDisconnectTimeout]
Defines the duration (in seconds) to wait after a trunk (BRI)
"Red" alarm (LOS / LOF) is raised, before the device
disconnects the SIP call. If this timeout expires and the
alarm is still raised, the device sends a SIP BYE message
to terminate the call. If the alarm is cleared before this
timeout expires, the call is not terminated, but continues as
normal.
The range is 1 to 3600. The default is 20.
Web: Disconnect Call on Busy Tone
Detection (ISDN)
EMS: Isdn Disconnect On Busy Tone
CLI: disc-on-bsy-tone-i
Determines whether a call is disconnected upon detection
of a busy tone (for ISDN).
[0] Disable = (Default) Do not disconnect call upon
detection of busy tone.