9. Troubleshooting
SIM 7D(P):
troubleshooting
NO POWER
POWER CORD NOT HOT
Check external power supply
Replace the power cord
POWER CORD NOT PLUGGED
Plug in power cord
MAINS SWITCH OFF
Switch ON
BACK TO STANDBY
TEMPERATURE OUT OF RANGE
INTERNAL TEMP.
Clean/replace air filter
EXTERNAL TEMP.
Cool down the room
HUMIDITY OUT OF RANGE
Decrease humidity in the room
VERY HIGH ALTITUDE
LAMP
Replace lamp
NO IMAGE
LAMP ON
NO SOURCE SELECTED
Select a source
NO SOURCE SIGNAL FOUND
NOT CONNECTED
Connect the source
Check wires and connectors
Check IG
LAMP OFF
PROJECTOR IN STANDBY
Switch to active state
Replace lamp
ARTEFACTS
STRETCHED / SHRUNK IMAGE
Adjust the Scaling setting
WRONG ORIENTATION
Adjust the Orientation setting
FLICKERING IMAGE
Replace lamp
Check the optical cables and Tx, Rx
NOICE
Check the IG
Check cabling and connections
POOR IMAGE
BAD ZOOM
Adjust lens zoom
BAD FOCUS
Adjust the lens focus
BAD SOFT EDGE
ELECTRONIC SOFT EDGE
Switch on soft edge
BAD BRIGHTNESS or
CONTRAST
Adjust the dimmer settings
Time Of Day
CLO
Clean the projection lens
Adjust brightness/contrast
NO CONTROL
NO RCU CONTROL
Remove blocking objects
Program the correct address
Insert new batteries
Image 9-2
166 R59770198 BARCO SIM 7D 13/02/2013