3 608 878 300 Tightening Technology | Bosch Rexroth AG 183/641
System 350 | 3 608 878 300/2019-03
5.6.11 Setting the trigger output
(1) Input, (2) Output
5.6.12 NOK lock and acknowledgement
(1) Input, (2) Output
A start is only possible after acknowledgement with NokAc.
If the NokAc signal is "high" when starting a tightening cycle (Cw), the NOK acknowledgement function
is activated. An NOK acknowledgement is only possible after process end (CyCmp) (lock). The worker
must wait for the CyCmp signal and have released the start switch (Cw “low” again). If he acknowledges
too early, the acknowledgement will have no effect on the system.
x.y En
x.y Prg0
x.y Prg1
x.y ResF
x.y Prg2
x.y Cw
x.y NOKAc
x.y Rdy
x.y NF
x.y NOK
x.y InCy
x.y CyCmp
x.y OK
x.y Ack0
x.y Ack1
x.y Ack2
1
2