3 608 878 300 Tightening Technology | Bosch Rexroth AG 617/641
System 350 | 3 608 878 300/2019-03
7.7.2.4 Motor release interruption at the LTS350D/LTE350D
At the XDN3 interface, see figure 7–41, the motor release can be interrupted via a potential-free opening
contact.
PIN 1 and 2 are equipped with a jumper at the factory to ensure that the motor is ready for operation.
Fig. 7–41: Interface XDN3
7.7.2.5 Inserting and connecting the modules
Proceed as follows to insert and connect the modules:
• Insert components in accordance with chapter Assembling the modular system (page 526)
• Insert the available interface modules in accordance with chapter Interface modules (IM) (page 527)
• Insert the socket for the hand-held nutrunner connection cable in the correct position in the plug on
the nutrunner handle and tighten the union nut connection by hand
• Insert the plug for the nutrunner connection cable in socket XDS1 (Figure 7–36) on the LTU350/1
servo amplifier and/or LTS350D/LTE350D and tighten the union nut connection by hand
• Establish the other required connections in accordance with Setting up the connections (page 528)
• Switch on the power supply for the BT or on/off switch on the SB
• Connect the PC for programming in accordance with chapter Connecting the PC for programming
(page 536) (not necessary if commissioning a complete package).
7.7.3 Configuring the tightening channel
The standard configuration of the ErgoSpin tightening channel is automatically configured during
commissioning. No configuration changes are required for basic commissioning. The configuration can
also be implemented manually at System Tightening channel configuration (see Offline
configuration: (page 576)), if you are using deviating versions, additional components, or working in
offline mode.
Channel configuration created offline with an ErgoSpin VarioLine (ESV) or pistol grip nutrunner
(ESM)
For reasons of securing the tightening system, the following restriction applies to tightening channel
configurations created offline which contain an ErgoSpin of type VarioLine (ESV) or of type pistol grip
nutrunner (ESM): the tightening controller does not accept this tightening channel configurations. The
tightening channel configuration can be sent to the tightening controller (Data Send … or
Data Send to …), it is, however, not accepted.
Table 7–39: Positions of the PIN plug in the LTS350D/LTE350D
PIN plug in
position:
Explanation
1
Motor-breaker Out
2
Motor-breaker In
General information on sending files can be found at Sending and saving (page 542).