3 608 878 300 Tightening Technology | Bosch Rexroth AG 477/641
System 350 | 3 608 878 300/2019-03
6.12.4 Configuring the PLUS Protocol connection in the BS350 operating system
The configuration window for PLUS in the BS350 operating system can be opened in two different ways.
This depends on the question whether the BS350 is connected to a tightening system ("online") or not
("offline"):
• Online: System PLUS configuration
• Offline: File New PLUS configuration
Connection parameters
Operation parameters
Table 6–152: Settings in BS350 for PLUS - Tandem parameters
Element Description
Port PLUS server port.
IP filter Default setting: 0.0.0.0 – allows communication with every tandem server
Fixed IP address entered – allows communication with only one entered server
Coupling no. Specified by Daimler.
Resync with Conn. Synchronization (block counter) after the connection to the server has been
established.
Ackn Timeout Waiting time within which a telegram must have been acknowledged (in
milliseconds).
Response Timeout Waiting time of a request until the response is given (in milliseconds).
Q1 repeat Specifies how often the data must be sent again after PLUS has given a negative
response.
Resync after Q1 Synchronization (block counter) after a negative response from the BS350
tightening system.
Users Parameter for data field in the PLUS Protocol
Error code Error code for non-tightened tightening positions (default: N31)
Table 6–153: Settings in BS350 for PLUS - OP
Element Description
OP Operation 1 to Operation 8 – Selects the operation for which the parameters are to
be set.
Active Specifies whether the operation selected is to be used.
Note: Operations are processed sequentially. The first inactive operation defines the
total number of active operations.
Delete OP Deletes the operation selected.
ID Unique identifier of the operation selected – cannot be edited! Only for BS350, is
not used in the PLUS Protocol.
Name Name for the operation selected, can be selected as desired. Only for BS350, is not
used in the PLUS Protocol.
Production point Specifies the production point at which the operation is performed.
ID filter Allows selecting/filtering certain areas from the complete ID If you enter “I" here, the
character is applied at the place in the PLUS ID code that is identified by “I". If you
enter an asterisk ("*"), the character is ignored.
ID_PosMask Individual positions from the complete ID code can be masked for further
processing in IndraLogic (IL), e.g. for program selection. If you enter "P" here, the
character is applied at the place in the PLUS ID code that is identified by "P". If you
enter an asterisk ("*"), the character is ignored.
ID type request/
ID type station
Defines the ID type inquired:
KNR (car body number), PNR (production number) LTR (carrier number) or VTI
(variable ID)
Operating mode Parameter for transferring the operating mode to the IL for execution. The IL requires
this information in case of a generic IL program. Whether or not this information is
used, depends on the IL.