3 608 878 300 Tightening Technology | Bosch Rexroth AG 209/641
System 350 | 3 608 878 300/2019-03
6.1.6 Tightening results from several steps of a tightening process
Results output is normally implemented from the last executed step. In OK cases this is usually the last
step in column A. In NOK-cases, it is the step that led to the tightening abort.
It is additionally possible to identify nine other steps as documentation steps. The results from these steps
are then stored in so-called docu buffers and provided for further processing.
Identification of the steps for results output
The steps 2A to 4A are identified as docu steps in this example ( -symbol in the step icon). Step 5A, the
last step, does not have to be identified as a docu step, since it is documented (identified as docu buffer
0) by default. Selection is implemented in Step characteristics at Save results. On the one hand,
selecting docu buffer 1–9 manages the number of the already used documentation options, and on the
other hand , order 1–9 also influences the order in which the results are entered.
Fig. 6–3: Identification of the steps for results output
If the last completed step is a documentation step, the result from the documentation step will not be
additionally output.
Assign the docu buffer according to the logical sequence in the tightening process.