3 608 878 300 Tightening Technology | Bosch Rexroth AG 317/641
System 350 | 3 608 878 300/2019-03
Fig. 6–63: Compact system for single-channel tightening system with system box, hand-held nutrunner, and results output on a
printer
6.5.1 Results output on printer
6.5.1.1 Configuration of the serial interface for results output
The necessary parameters are configured via the configuration of the interface. In the CS351 compact
system and the KE350 communication unit, the installed serial interface (X3C1) can be configured.
To configure the serial interface of the CS351 Compact System:
1. In the BS350 operating system, click System Tightening channel configuration.
This function calls up the current configuration of a tightening channel.
(1) Data output on a printer
Due to the conduction physics, cross-talk between transmission path (TX) and receipt path (RX) may
result with open, shielded lines (e. g. RS232). As a consequence of this effect, the relevant signals and
signal levels can no longer be correctly presented and interpreted. This results in loops in the transmission
and/or receipt routine of the operating system.
Always connect lines with the characteristics specified above with a corresponding communication
partner in order to avoid the undesired cross-talk effect.