3 608 878 300 Tightening Technology | Bosch Rexroth AG 457/641
System 350 | 3 608 878 300/2019-03
6.10.2 Settings in the BS350 operating system
The Rexroth IPM Protocol is configured on the compact system and the KE in an identical way. The
following settings have to be made in the BS350 operating system in the specified order:
1. Configuration of Rexroth IPM Protocol
2. "Select ID-code filter" dialog
6.10.2.1 Configuration of Rexroth IPM Protocol
The configuration window for Rexroth IPM Protocol in the BS350 operating system can be opened in two
different ways. This depends on the question whether the BS350 is connected to a tightening system
("online") or not ("offline"):
Online: As of version V2.500 of the Rexroth Tightening System 350: System IPM configuration
If no configuration file is stored on the tightening controller, the following message is output and the
configuration window is not opened:
There is no IPM configuration file available on the controller. The configuration view cannot be
opened.
Offline: As of version V2.500 of the Rexroth Tightening System 350: File New IPM
configuration
Configuration files for Rexroth IPM Protocol with ipm filename extension can be opened
(File Open…), saved (File Save… or File Save As…) and printed in the BS350-specific report
format (File Print).
The title bar of the configuration window for Rexroth IPM Protocol in the BS350 operating system differs
according to the operating mode:
In the online mode, the name of the title bar is IPM configuration: CS for compact systems or IPM
configuration: KE for modular systems.
In the offline mode, the name of the title bar is IPM configuration: New1, New2, …
The fields in the entry window have the following meanings:
Table 6–141: Configuration settings Rexroth IPM Protocol
Element Type Value range Standard value Comment
Host IP address Text; read-only local local
IPM IP address TCP/IP V4 address TCP/IP V4 address 192.168.0.1 IP address of the IPM gateway
to which the data is to be sent
(target address)
IPM port TCP/IP V4 port TCP/IP V4 port 5501 IP port of the IPM gateway to
which the data is to be sent
(target address)
Up to V2.400
ID code mask
Text maximally 255
characters
The IPM data record has
different (text) data fields to
which flexible parts of the
ID-code can be mapped, see
example on page 459. This
element can be used for this
purpose, whereas the following
characters are admissible for ID
code mask (IDCodeMask):
–_
Placeholder; character at
this position is ignored
–*
New placeholder character
to provide a clearer view
–I
Character at the position
marked by I is taken over in
IPM ID code

Table of Contents