EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Quality Code

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
206/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.1.4 Quality code
The quality code (QC) describes whether a tightening has been evaluated as OK or NOK. If an NOK
evaluation is output, the cause will also be listed.
For information about creating a quality code assignment table, refer to the "Project planning"
documentation of the Rexroth Tightening System 350
In addition to the quality code, the PLC OK/NOK signal must also be used for the evaluation.
Table 6–6: Quality codes and their meaning
Quality code
Monitoring function NOK
1
All other monitoring functions Category
1 – All OK System
130 Remove start signal ((C)Cw = 0) OK/NOK System
130 Remove enable (En = 0) OK/NOK System
131 Timeout sync/rework (t+ Sync/RW) OK/NOK System
131 Timeout application (t+ app) OK/NOK System
132 Synchronization (sync) OK/NOK System
133 Rework (RW) OK/NOK System
135 Spindle bypass (ByPass) OK/NOK System
136 NOK step (max. NOK) OK/NOK System
137 Torque redundancy (RedT) OK/NOK System
138 Angle redundancy (RedA) OK/NOK System
139 Start-up test (StartUp) OK/NOK System
129 System error (fault) OK/NOK System
128 Loosen (SoRel) OK/NOK System
2A+, OK All
4A-, OK All
8M+, OK All
10 A+, T+, OK All
12 A-, T+, OK All
16 M-, OK All
18 A+, T-, OK All
20 A-, T-, OK All
32 G+, OK All
34 A+, G+, OK All
36 A-, G+, OK All
40 T+, G+, OK All
42 A+, T+, G+, OK All
44 A-, T+, G+, OK All
48 T-, G+, OK All
50 A+, T-, G+, OK All
52 A-, T-, G+, OK All
64 G-, OK All
66 A+, G-, OK All
68 A-, G-, OK All
72 T+, G-, OK All
74 A+, T+, G-, OK All
76 A-, T+, G-, OK All
80 T-, G-, OK All
82 A+, T-, G-, OK All
84 A-, T-, G-, OK All
128 NOK OK/NOK System

Table of Contents

Related product manuals