EasyManua.ls Logo

Bosch Rexroth Tightening System 350 - Motor-Breaker; Switching on the Tightening Cell

Bosch Rexroth Tightening System 350
641 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
534/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
7.2.7 Motor-breaker
in chapter Construction guidelines from page 59.
7.2.8 Switching on the tightening cell
7.2.8.1 Compact system
LED displays
Fig. 7–9: LED on the front
NOTICE
Overvoltage
Components may be damaged
The CS on/off switch may only be switched on once all the cables have been connected and
checked for proper fit.
Table 7–6: LED modes
LED Display Diagnosis
Off No power supply or low-voltage power supply
available
Blue Power supply and low-voltage power supply
available
Green Ready for operation
Green, flashing Sequence control active, not ready for operation,
no system error
Red, flashing System error
OK/NOK Green Tightening case evaluation: OK
Red, flashing Tightening case evaluation: NOK
Off Motor contactor not operated
Green Motor contactor operated
Red/green, flashing Servo amplifier initialization
Red Motor contactor error
FG Green Servo amplifier release
Off No servo amplifier release
RUN/STOP
(only for
CS... IL)
Green IndraLogic running
Red IndraLogic stopped
ERROR
(only for
CS... IL)
Red, flashing IndraLogic error

Table of Contents