258/641 Bosch Rexroth AG | Tightening Technology 3 608 878 300
System 350 | 3 608 878 300/2019-03
6.2.8 Error messages in connection with Ethernet/FTP
Table 6–23: Ethernet/FTP error messages
Error number
(internal)
Error class Affected
Components
Error text Error causes/
troubleshooting
2014 1 KE / CS Initialization error TCP/IP
2015 1 KE / CS Internal error TCP server
2023 3 KE / CS CF card warning level
2024 4 KE / CS CF card full
2027 3 KE / CS ID code cannot be read
2028 3 KE / CS CF card access error
2029 4 KE / CS Transfer list error
2030 1 KE / CS Internal error
2031 3 KE / CS Server access error
2032 3 KE / CS CRC error settings
2033 4 KE / CS Read transfer list error
2037 4 KE / CS Write transfer list error
2038 3 KE / CS Create transfer list error
2039 4 KE / CS Delete transfer list error
2040 3 KE / CS Error App. res. file creation
2041 3 KE / CS SE res. file creation error
2042 3 KE / CS Read results file error
2043 4 KE / CS ATA directory does not exist
2044 3 KE / CS Create directory
2045 3 KE / CS Create file ID Code
2046 4 KE / CS FTP server write access error
2047 3 KE / CS Error: Close FTP connection
2048 4 KE / CS Error: Login FTP server
2049 4 KE / CS Error: FTP directory access
2051 3 KE / CS IP address not found by server
2218 1 KE / CS Compact flash card missing
2219 1 KE / CS Error file system mass storage
2228 3 KE / CS Internal error Ethernet driver
2229 3 KE / CS Internal error Ethernet driver

Table of Contents